  • Ian created an article,

    How to replace the UV Tube - ROTOR(+)

    Introduction The manufacturer of the UV Tubes fitted to the ROTOR(+) recommend replacement every 12 months or 100 hours whichever comes first. The UV will conitinue to work past this time but the e...

  • Ian created an article,

    What is the volume transferred when pinning from liquid to agar? - PIXL

    Answer: When transferring from liquid to agar on the PIXL the volume transferred is approximately 226nl. These results are based on pinning from a Corning™ Costar™ 96-Well, Cell Culture-Treated, Fl...

  • Ian created an article,

    MSM 400 - Dropping Touchscreen

    Introduction Touchscreen computers are fitted as standard to all MSM400's but older MSM 300's which have had an upgrade will also have been fitted with a touchscreen computer. It is not unusual for...

  • Ian created an article,

    Can I use the PIXL to image multi well plates?

    Answer : No In the past we have tried to assist customers with imaging multi-well plates containing colonies. We have now stopped supporting this method. Due to image reflections and other problems...

  • Ian created an article,

    How to fix the keyboard / mouse Bluetooth connection - PIXL

    Introduction The PIXL is supplied with a Bluetooth mouse and keyboard. These are set up and tested before leaving Singer Instruments. Once the dongle has been fitted to the PIXL USB port and both t...

  • Ian created an article,

    Can a 150mm Petri Dish be used in the PhenoBooth?

    Answer: No - It is not possible to use a 150mm Petri Dish in the PhenoBooth

  • Ian created an article,

    What is the accuracy of the PIXL?

    Answer The PIXL has an accuracy of: X Axis Y Axis +/-0.05 +/-0.05 If you require more information please contact technicalsupport@singerinstruments.com for assistance.

  • Ian created an article,

    What is the accuracy of the ROTOR(+)?

    Answer The ROTOR(+) has an accuracy of: X Axis Y Axis +/-0.05mm +/-0.005mm If you require more information please contact technicalsupport@singerinstruments.com for assistance.

  • Ian created an article,

    How to replace the halogen lamp on an MSM 300/ 400

    Introduction Older MSM 300/ 400's were fitted with a Halogen Bulb. We no longer stock these but the details are here  Do you stock the Halogen Lamp replacements? Another option is to upgrade to an ...

  • Ian created an article,

    How to change the screen resolution in the ROTOR HDA Software (Video)

    Introduction The screen resolution for the ROTOR HDA can be changed depending on the laptop or touchscreen computer being used. Note: This article only applies to ROTOR HDA's supplied before July ...