Does it matter how the plates are loaded into the PIXL?
Answer: There are some requirements that need to be followed when loading plates into the PIXLLids:Lids must be removed before running the PIXL.Source Plate:Ensure that you have the correct source ...
-
Array 4 liquid to 1 Agar - Change all plates at repeat on the ROTOR(+)?
Answer: The standard array liquid to agar program/ routine supplied with the ROTOR software allows the user to switch only the Black (target plate) at repeat when condensing 4 liquid source plates ...
-
How to set up the needle on an MSM
Answer: The PDF document attached explains how to fit and then set up the needle in your MSM. If you require more information please contact technicalsupport@singerinstruments.com for assistance.
-
Recognise your MSM 100
Picture: Below is a picture of an MSM 100. The first of the MSM's. Singer Instruments are no longer able to fully support the MSM 100 due to the lack of available parts. If you do experience any pr...
-
What are the pinning positions when pinning from 4 x 384 to 1 x 1536 on the ROTOR(+)?
Answer : The diagram below demonstrates the pinning positions when creating a 1536 pad from 4 x 384 pads. Source Plate Target Plate 4 x 384 (a,b,c,d) 1 x 1536 If you require more information ...
-
Software Installation - IMPORTANT
Singer Instruments will NOT be held responsible for issues caused by software installed on any Singer-supplied computers that was not provided by Singer Instruments .Software not provided by Singer...
-
What is Capillary action?
Answer When a pipette tip is placed at or below the liquid surface, a small volume of the liquid may get pulled up into the tip without any external pressure being applied. This is because the adhe...
-
What is Liquid Level Detection (LLD)?
Answer Liquid Level Detection (LLD) is when SQWERTY moves slowly down the z-axis towards the liquid surface aspirating small volumes as it goes. When liquid is aspirated rather than air, SQWERTY wi...
-
Can I use the PIXL to image multi well plates?
Answer : NoIn the past we have tried to assist customers with imaging multi-well plates containing colonies. We have now stopped supporting this method.Due to image reflections and other problems ...
-
What model of ROTOR do I have - ROTOR / ROTOR+?
Answer: In 2021 Singer Instruments developed a new and updated version of the ROTOR which has been produced since 2006.The original ROTOR was updated to ROTOR+ due to the discontinuation of some of...