Casio EG800 PDA (MSM300) User Manual
User Guide : The first document attached is taken from an original manual we used to send to our new MSM 300 customers. This particular manual has been written for users who have the Casio EG800 PD...
-
What is 'Overshoot' in the ROTOR(+) software?
Answer : In the ROTOR(+) software there is an option called 'Overshoot' which is explained in more detail in the attached PDF document, with diagrams. 1 2 3 Parts of the Pad Gripper He...
-
Can we re-use PlusPlates and RePads?
Answer : Singer PlusPlates and RePads are not recommended for re-use. We supply them in sterile packaging intended for one use only to reduce any possibilities of contamination. Reasons: Sterility...
-
MSM Manual User Guide
User Manual : The handbook attached to this article has been taken from an original document which was written using old word processor software. Unfortunately during the conversion to a readable f...
-
What are the V2 Pins for on the ROTOR?
Answer : In 2016 due to changes in the size of the V2 PlusPlates to meet new Standards Singer Instruments modified the size of the location pins on the turntable and station black to compensate. W...
-
How to download Log Files on the ROTOR(+) (Video).
Answer : If the ROTOR(+) experiences some random faults which are not easy to diagnose the Technical Support Team may ask for the log files. The video below demonstrates access to the Log File tab ...
-
Does the ROTOR(+) work with Laboratory Information Management Systems (LIMS)?
Answer : Below is a typical question we have received regarding the use of a Laboratory Information Management System (LIMS) system "We are using a Laboratory Information Management System (LIMS) ...
-
Can we re-use the Stinger Pins?
Answer : Stinger pins are designed to be re-used multiple times. They can be autoclaved both in and out of the cartridge. If autoclaving in the cartridge remove the bottom of the tray to expose th...
-
MSM 200 User Manual
User Manual : The handbook attached to this article has been scanned from an original document. If you need to reset the limits of the dish described in section 5 please use the drawing document di...
-
Can I autoclave the ROTOR(+) Dump Drawer and Pad Hopper?
Answer : The ROTOR Dump Drawer and the Pad Hopper, including the Pad Support block can be autoclaved. Dump Drawer Pad Hopper with Support Block If you require more information please contact te...